TC12 General Handbook
666/HB/43100/000 Page 2-1 Issue 9
2. SPECIFICATION
2.1 Mains Voltage Ranges
Instation 98 - 132Vrms / 198 - 264Vrms
Outstation 85 - 264Vrms
Instation Test Set 98 - 132Vrms / 198 - 264Vrms
Outstation Test Set 99 - 121Vrms / 216 - 264Vrms
2.2 Mains frequency range
All TC12 equipment will work from 47Hz to 63Hz.
2.3 Mains Current
2.3.1 Instation
Instation Cabinet without racks 1.0A at 240V
ITU Rack (Fully equipped) 200mA at 240V
Digital Output Rack (Fully equipped) 4.5A at 240V
1024 LEDs at 24V 25mA per LED
Digital Output Rack (Fully equipped) 2.75A at 240V
1024 LEDs at 24V 15mA per LED
The figures above are added together for the system used:
An Instation cabinet with two ITU racks 1.0 + 0.2 + 0.2 = 1.4A
An Instation cabinet with two 15mA Digital output racks 1.0 + 2.75 + 2.75 = 6.50A
2.3.2 Outstation
OTU rack including 4 Detector cards 250mA at 240V
2.3.3 Test Sets
Instation Test Set 400mA at 240V
Outstation Test Set 100mA at 240V
2.4 Temperature and Humidity Requirements
Instation will work at 0 to 40 Deg C.
Humidity 20%-80% non-condensing.
OTU will work at -15 to 75 Deg C.
Humidity 96% at 40 Deg C non condensing.