TC65Smart
User Manual
Rev. 2-1.0 21
TC65_DTR_OFF
0x12 0x00-
0xFF
The command sets up the mode of hardware
disabling of the enabled module by the DTR
signal. The value of the operand determined
the delay in x100ms (0-25.4c) since the
time of removal of the active DTR signal.
(< 0V) until the time of automatic disabling
of the module. The value 0xFF disables the
automatic disabling mode. The value 0x00
initiates the automatic disabling at once
after the signal transmission. The value is
saved in the non-volatile memory. The
value on default is 0xFF (disabled). During
the timing the indicator “PWR/STATE”
flashes intermittently.
<aFE12xx>
SIM_change
0x40 0x00,
0x01
The command initiates the procedure for
SIM card switching over. The operand
determines the number of the required SIM
mount (0 – the “SIM1” mount, 1 – the
“SIM2” mount). The switching procedure
goes along with the CCIN signal
transmitted to the module, which makes it
possible to disable the SIM interface at the
switching moment, and the automatic start
of registration in the network after the
procedure is completed. If the SIM card
“tray” is unavailable in the mount required
by the command, the switching procedure is
disabled. If the required mount is already
active, the operator is repeatedly registered
in the network. The selected value of the
mount number is saved in the non-volatile
memory of the controller. The last selected
mount is automatically selected upon
power-on. Selection of the mount is
indicated by the corresp. indicators “SIM1”
and “SIM2”.
<aFE4000> /
<aFE4001>
I2C_adr
0x70 0x00 –
0x7F
The command makes it possible to specify
the Controller address on the bus-line I2C.
On this address TC65 will address to the
Controller. It should not be forgotten that
the address byte of the bus-line I2C
contains the address in the higher 7 bits.
The lower bit is used as a reading/recording
marker. If this command transmits the
address 0x7F, the recording commands
must be transmitted to the address 0xFE, the
reading commands – to 0xFF (the
instruction operand shifted to the left by 1
position). It is saved in the non-volatile
memory. The initial value is 0x7F (0xFE-
recording, 0xFF-reading). The controller
jumps to the new address at once after the
command is received.
<aFE7002> -
switching over
from the
address 0x7F
(0xFE/0xFF)
to the address
0x02
(0x01/0x00)