Vista de pagina 11
Camera part and connector definition
12
Siemens Building Technologies
Fire Safety & Security Products 01.2009
5.2 Connector pin definition
5.2.1 Digital I/O terminal
GND
AI2
1. External alarm input-2
2. Becoming BW/CL enforced input when the Digital
Input Mode is set to BW Mode in the Configuration-
Alarm page
RS485- / + RS485 signal output port for telemetry control
COM
AO
Alarm output port
GND
Al1
External alarm input-1
5.2.2 DC Auto Iris port
PIN 1 Damp -
PIN 2 Damp +
PIN 3 Drive +
PIN 4 Drive
5.2.3 Power IN connector
RED: Power +
WHITE: Power -
Power: 12 V DC or 24 V AC
5.2.4 Video output connector
Video Signal Output Composite video output
5.2.5 IP/TV switch
IP Video out through Ethernet
TV BNC composite video out for installation purposes
5.2.6 Default/reset buttons
DEFAULT
Return to factory default by pressing button for 5
seconds
RESET
System re-start