Working with the TS Adapter IE
7.6 Setting IP Parameters of TS Adapter IE for the First Time
TS Adapter IE
48 Manual, 06/2008, A5E00977705-02
7.6.2 Setting IP Parameters by Direct Connection with the SIMATIC Manager
Requirement
You have a free Ethernet port on your PG/PC.
Procedure
1. Connect the Ethernet port of your PG/PC to the Ethernet port of the TS Adapter IE.
2. Connect the TS Adapter IE to your power supply.
3. In the SIMATIC Manager under "Options > Set PG/PC Interface", set the "S7ONLINE
(STEP 7)" access point to your PG/PC's interface card to which you have connected the
TS Adapter IE.
4. From the SIMATIC Manager menu choose "PLC > Edit Ethernet Node".
5. Click "Help" to find out more about what to do next.
Result
You can now open the configuration interface of the TS Adapter IE in a browser via Ethernet
at the address http://<IP address>.
See also
Power Supply (Page 29)
Opening the Configuration Interface by Direct Connection in a Browser (Page 57)