Siemens MC35 Especificaciones Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 42
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
MC35i Terminal Hardware Interface Description
Confidential / Released
s
MC35i_T_HD_v02.00a Page 23 of 42 16.02.2007
3.5.2 RS-232 interface
Via RS-232 interface, the host controller controls the MC35i Terminal and transports data.
Figure 5: Pin assignment RS-232 (D-Sub 9-pole female)
Table 11: 9-pole D-Sub (female) RS-232
Pin no. Signal name I/O Function
1 /DCD O Data Carrier Detected
2 /RXD O Receive Data
3 /TXD I Transmit Data
4 /DTR I Data Terminal Ready
Attention: The ignition of MC35i Terminal is activated via a
rising edge of high potential (+3 ... +15 V)
5 GND - Ground
6 /DSR O Data Set Ready
7 /RTS I Request To Send
8 /CTS O Clear To Send
9 /RI O Ring Indication
MC35i Terminal is designed for use as a DCE. Based on the conventions for DCE-DTE
connections it communicates with the customer application (DTE) using the following
signals:
Port TxD @ application sends data to TXD of MC35i Terminal
Port RxD @ application receives data from RXD of MC35i Terminal
The RS-232 interface is implemented as a serial asynchronous transmitter and receiver
conforming to ITU-T V.24 Interchange Circuits DCE. It is configured for 8 data bits, no parity
and 1 stop bit, and can be operated at bit rates from 300bps to 115kbps. Autobauding
supports bit rates from 4.8kbps to 115kbps. Hardware handshake using the /RTS and /CTS
signals and XON/XOFF software flow control are supported.
In addition, the modem control signals /DTR
*)
, /DSR, /DCD and /RING are available. The
modem control signal RING (Ring Indication) can be used to indicate, to the cellular device
application, that a call or Unsolicited Result Code (URC) is received. There are different
modes of operation, which can be set with AT commands.
*)
Note: The /DTR signal will only be polled once per second from the internal firmware of
MC35i.