1.9 Recommended Cable Specifications
The following table outlines the cable recommended for connection of an inte-
grated security system:
Recommended Cable Specifications Communication
Type
Core Pairs AWG Stranding Wire Type Insulation Shield Jacket
4 2 28 7 x 36 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ braided shield
PVC
6 3 28 7 x 36 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ braided shield
PVC
RS485
8 4 28 7 x 36 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ braided shield
PVC
4 2 24 7 x 32 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC
6 3 24 7 x 32 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC
RS232
8 4 24 7 x 32 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC
4 2 24 7 x 32 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC
6 3 24 7 x 32 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC
RS422
8 4 24 7 x 32 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC
8 4 24 Solid Bare
Copper
Polyethylene Unshielded PVC RJ-45
8 4 24 7 x 32 Tinned
Copper
Polyethylene Unshielded PVC
8 4 24 Solid Bare
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC RJ-12
8 4 24 7 x 32 Tinned
Copper
Polyethylene Aluminium foil- Polyester tape
/ no braid
PVC
Power
(12/24 V DC)
2 1 18 19 x 30 Tinned
Copper
Polyethylene Unshielded PVC
The previous table provides a guideline for selecting an appropriate cable type only. Other cable types
are also compatible with the system and can be used to achieve the same results.
1.10 Programming and Firmware Download
The AFI5100 is programmed using the host software application via the ACC, or
using the FLN Configurator Field Service Tool application. Please refer to the ap-
propriate User’s Guide for more Information.