Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
84 Adding an RMON History Control
1
Figure 48: RMON History Controls Table
1. InsertRecord
2. Click InsertRecord. The RMON History Controls form appears.
10
7
8
1
2
3
4
5
6
9
Figure 49: RMON History Controls Form
1. Index Box 2. Port Box 3. Requested Buckets Box 4. Granted Buckets Box 5. Interval Box 6. Owner Box 7. Apply
Button 8. Delete Button 9. Reload Button
3. Configure the following parameter(s) as required:
Parameter Description
Index Synopsis: 1 to 65535
Default: 1
The index of this RMON History Contol record.
Port Synopsis: 1 to maximum port number
Default: 1
The port number as seen on the front plate silkscreen of the switch.
Requested Buckets Synopsis: 1 to 4000
Default: 50
The maximum number of buckets requested for this RMON collection history group of
statistics. The range is 1 to 4000. The default is 50.
Granted Buckets Synopsis: 0 to 65535
Vista de pagina 97