Connecting up
SCALANCE W788-xPRO / W74x-1PRO/RR
40 A5E02280448-02, Release 11/2008
Grounding
CAUTION
Damage to the device due to potential differences
To fully eliminate the influence of electromagnetic interference, the device must be
grounded. There must be no potential difference between the following parts,
otherwise the device or other connected device could be severely damaged:
Housing of the SCALANCE W-700 and the ground potential of the antenna.
Housing of the SCALANCE W-700 and the ground potential of a device
connected over Ethernet.
Housing of the SCALANCE W-700 and the shield contact of the connected
Ethernet cable.
Connect both grounds to the same foundation earth or use an equipotential bonding
cable.
Interruption of the power supply
CAUTION
Damage to the Ethernet interface
Repeated fast removal and insertion of the Ethernet cable when using Power-over-
Ethernet and when there is a redundant power supply can cause damage to the
Ethernet interface.
Avoid repeatedly removing and inserting the Ethernet cable when using Power-
over-Ethernet and a redundant power supply.
FM warning notice
When operated in potential hazardous areas:
WARNING - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR
DIVISION 2
WARNING - DO NOT OPEN WHEN ENERGIZED
WARNING - DO NOT DISCONNECT EQUIPMENT WHEN A FLAMMABE OR
COMBUSTIBLE ATMOSPHERE IS PRESENT