Technical data
6.1 Technical specifications W761/W722/W721 RJ-45
SCALANCE W760/W720
28 Operating Instructions, 03/2015, C79000-G8976-C322-04
SCALANCE W761/W722/W721
Wireless interface
Antenna connector
Quantity
1
Design
R-SMA female
Impedance
50 Ω nominal
Frequency range 2412 ... 2480 MHz
4920 ... 5875 MHz
Electrical data
Power supply
Supply voltage
24 VDC Safe Extra Low Voltage (SELV)
Permitted range
19.2 to 28.8 VDC
Design
Terminal block, 3 terminals
Properties
Electrically isolated, non-redundant design
Fusing
2.5 A / 24 VDC
Current consumption
Typical
150 mA
Power loss at 24 VDC
Typical
3.6 W
Permitted ambient conditions
Ambient temperature During operation with the rack in-
stalled horizontally
0 to +55
During operation with the rack in-
stalled vertically
0 to +55
During storage
-40 to +85
During transportation
-40 to +85
Relative humidity
During operation
95% at 25 °C, no condensation
Operating altitude During operation 2,000 m above sea level at max. 55 °C
ambient temperature
Contaminant concentration According to IEC 60721
Design, dimensions and weight
Degree of protection
IP20
Weight
130 g
Dimensions (W x H x D)
50 x 114 x 74 mm
Installation options
Installation on a DIN rail
Mean time between failure (MTBF)
at 40 °C ambient temperature
106.51 years