13
Screw terminal 1
Spring-loaded terminal
2
Thermistor motor protection relays for PTC thermistors (type A PTCs)
All of the devices with the exception of 24 V AC/DC have electrical isolation
1)
Protective separation up to 300 V according to DIN/VDE 0106
2)
Information regarding the holding on supply failure, refer to Catalog LV 1, chapter 7
3)
Reset using the reset button or by interrupting the control supply voltage
Version Reset Contacts Control supply Order No.
voltage
Compact evaluation units, 22.5 mm wide, monostable, closed-circuit current principle, 1 LED
Auto 1 CO 24 V AC/DC 3RN1000-
AB00
110 V AC 3RN1000-
AG00
230 V AC 3RN1000-
AM00
Standard evaluation units, 22.5 mm wide, monostable, closed-circuit current principle, 2 LEDs
Auto 1 NO + 1 NC 24 V AC/DC 3RN1010-
CB00
110 V AC 3RN1010-
CG00
230 V AC 3RN1010-
CM00
24–240 V AC/DC 3RN1010-
CW00
2 CO 24 V AC/DC 3RN1010-
BB00
110 V AC 3RN1010-
BG00
230 V AC 230 V 3RN1010-
BM00
2 CO hard-gold-plated 24 V AC/DC 3RN1010-
GB00
Manual/ 1 NO + 1 NC 24 V AC/DC 3RN1011-
CB00
remote
3)
110/230 V AC 3RN1011-
CK00
Short circuits are detected in the sensor circuit Manual/ 2 CO 24 V AC/DC 3RN1011-
BB00
remote
3)
110 V AC 3RN1011-
BG00
230 V AC 3RN1011-
BM00
2 CO hard-gold-plated 24 V AC/DC 3RN1011-
GB00
Holding on supply failure
2)
Manual/auto/ 1 NO + 1 NC 24 V AC/DC 3RN1012-
CB00
remote 110/230 V AC 3RN1012-
CK00
Manual/auto/ 2 CO 24 V AC/DC 3RN1012-
BB00
remote 110 V AC 3RN1012-
BG00
230 V AC 3RN1012-
BM00
2 CO hard-gold-plated 24 V AC/DC 3RN1012-
GB00
Manual/auto/ 2 CO 24 V AC/DC 3RN1013-
BB00
remote 24–240 V AC/DC 3RN1013-1BW10
3RN1013-2BW00
2 CO hard-gold-plated 24–240 V AC/DC 3RN1013-1GW10
3RN1013-2GW00
Evaluation units for 2 sensor circuits, alarm and trip, 22.5 mm wide, monostable, closed-circuit current principle, 3 LEDs
Manual/auto/ 1 NO + 1 NC 24–240 V AC/DC 3RN1022-
DW00
remote
Evaluation units for 6 sensor circuits, multi-motor protection, 45 mm wide, monostable, closed-circuit current principle, 8 LEDs
Test/reset button, holding on supply failure
2)
Manual/auto/ 1 NO + 1 NC 24–240 V AC/DC 3RN1062-
CW00
remote
Bistable evaluation units, 22.5 mm wide
Test/reset button, holding on supply failure
2)
, Manual/auto/ 2 CO 24–240 V AC/DC 3RN1013-
BW01
short circuits and wire breakage in the remote
sensor circuit are detected and displayed,
bistable version, not tripped when the
control supply voltage fails
Terminal A1 is connected to the
common of the changeover contact
Holding on supply failure
2)
,
short circuits are detected in the sensor circuit
Holding on supply failure
2)
, short circuits
and wire breakage in the sensor circuit are
detected and displayed, wide-range voltage
with screw terminals with protective
separation
1)
Test/reset button, holding on supply failure
2)
;
the evaluation circuit for “alarm” uses an NO
contact in the open-circuit principle
14 | 15
Monitoring Relays