SIMATIC FS600 laser scanner
PROFIsafe laser scanner
3/103
Siemens FS 10 · 2008
3
Technical specifications
Type PROFIsafe laser scanner
Protective field
Detection range 0 ... 4 m
Luminance factor
min. 1.8 %
Object size and diameter
70 mm (cylindrical test body)
Response time
• dual evaluation (2 scans) 80 ms (only laser scanner without
PROFIBUS system times)
• adjustable up to 16 scans
640 ms (only laser scanner with-
out PROFIBUS system times)
Number
4 (can be switched via
PROFIBUS)
Safety category
Category 3 to EN 954-1, type 3 to
IEC 61496-1 or EN 61496-3
Output
PROFIBUS (PROFIsafe profile)
Start
Start test and start inhibit can be
set separately
Restart
160 ms to 10 s
(can be set or is manual)
Protective field supplement
• For deactivated dust suppression 83 mm
• For activated dust suppression
- protective field size < 3.5 mm 83 mm
- protective field size > 3.5 mm
100 mm
• Additional supplement in the case
of existing retro-reflectors or highly
reflective surfaces (e.g. certain
metals or ceramics) in the scan
plane
- more than 1.2 m behind the pro-
tective field line
0 mm
- in protective field or up to 1.2 m
behind the protective field line
110 mm
Warning field
Detection range 0 ... 15 m
Luminance factor
min. 20 %
Object size
150 × 150 mm
Response time
• dual evaluation (2 scans) 80 ms (only laser scanner without
PROFIBUS system times)
• adjustable up to 16 scans
640 ms (only laser scanner with-
out PROFIBUS system times)
No. of warning fields
4 (can be switched via
PROFIBUS)
Output
PROFIBUS
Contour measurement
Detection range 0 ... 50 m
Luminance factor
min. 20 %
Output
RS 232 serial interface
via infrared interface
Radial resolution
5 mm
Lateral resolution
0.36 °
Supply voltage
• Via external supply 24 V DC (+20 % / -30 %)
•Note
The power pack for the external
power supply must have a safe
line separation to IEC 60742 and
must bridge brief power failures of
up to 20 ms.
Overcurrent protection
Fuse 1.25 A (medium slow)
Current consumption
350 mA typical
Inputs
Restart/reset Connection of a command device
for "with restart inhibit" mode
and/or device resets, monitored
dynamically
Signal definition
• High (logical 1) 16 ... 30 V
• Low (logical 0)
< 3 V
Control cable
• Length Max. 50 m (cable cross-section:
0.5 mm
2
, shielded)
Field pair changeover
Field pair switchover via
PROFIBUS (PROFIsafe profile)
RS232 interfaces via
infrared interface
For device parameterization and
field definition
Optics
Rotation angle 190 °
Angle resolution
0.36 °
Lateral tolerance
• without assembly system
(for rear of enclosure)
± 0.18 °
• with assembly system
(for mounting surface)
± 0.22 °
Scan rate
25 scans/s or
40 ms/scan
Laser protection class
• to standard EN 60825-1, class 1 (eye safe)
wave length
905 nm
beam divergence
2 mrad
Time Base
100 s
Type